Horizontal Sidewall Standard Response, Standard Coverage, K-factor=5.6
Horizontal Sidewall Standard Response, Standard Coverage, K-factor=5.6
Light hazard/Ordinary hazard
3 mm bulb
Designed for use in applications where aesthetics must be considered or where building construction makes the installation of standard pendent or upright sprinklers impractical
Vertical sidewall sprinkler can be installed in either the pendent or upright position along a wall or the side of a beam and just below a smooth ceiling.
x
Upright Pendent and Recessed Pendent Sprinklers
Upright Pendent and Recessed Pendent Sprinklers
Standard Coverage & Standard Response Sprinklers are intended for use in fire sprinkler systems designed in accordance with the installation rules recognized by the applicable Listing or Approval agency. There are two types of response elements: bulb and solder Upright, Pendent & Recessed Pendent
Light hazard/Ordinary hazard
Light hazard K=2.8 (40,3)
3 mm bulb
x
Royal Flush II" Concealed Pendent Sprinklers
Quick & Standard Response, Standard Coverage, K-factor=5.6
Royal Flush II" Concealed Pendent Sprinklers
Light hazard/Ordinary hazard
5 mm bulb (standard) 3 mm bulb (quick)
Concealed in an enclosed escutcheon plate with flat cover for use in those applications where aesthetics is a primary consideration
Separable, two-piece design of the mounting cup and cover plate allows installation of the sprinklers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling
Internally threaded closure with 1/2" (12,7 mm) of adjustment
Available with optional dust and air seal K Facto r K=5.6 (80,6) Thread Size 1/2" NPT
Solder type . The TYCO Model ESFR-25 Pendent Sprinklers are listed by UL for Specific Applications with a ceiling height greater than 45 ft. (13,7 m) up to and including 48 ft. (14,6 m), and a storage arrangement up to and including 43 ft. (13,1 m)
Direct attack on burning fuel by improved heavy sprinkler discharge
Patented frame design substantially reduces the frame shadow effects that often produce non-uniformity in spray pattern
Novel orifice seal and unique fast response link design are the very latest in sprinkler technology K Facto r K=25.2 (362,9) Thread Size 1" NPT or ISO 7-R1 Approva ls UL, C-UL, FM, NYC, LPCB, VdS Temperatu re 165°F/74°C, 214°F/101°C Sprinkler Finish Natural Brass
x
Alarm Check Valve
300 psi (20,7 bar) 2-1/2" to 8" (DN65 to DN200)
Vertical or Horizontal* Installation
Two-Piece Flush Escutcheon, 3/4" NPT & ½” NPT
Two-Piece Flush Escutcheon, 3/4" NPT & ½” NPT
Styles 10, 15, 20, 30, 40, 50, & 70
Consists of a mounting plate and closure for finished appearance in ceilings or soffits
Intended for use in areas with finished
ceilings or walls, and the adjustment provided by these escutcheons reduces the accuracy to which fixed piping to the sprinklers must be cut, while providing a decorative recessed sprinkler installation
Primarily designed for use with standard spray, quick response sprinklers and the Designer residential sidewall sprinklers
Maximum 1/2" to 3/4" adjustment
x
Red-E Cabinet Integrated Deluge Fire Protection Package
Deluge Valve with Remote-Resetting Trim 2" to 8" (DN50 to DN200)
Deluge Valve with Remote-Resetting Trim 2" to 8" (DN50 to DN200)
Deluge Valve, External Resetting Diaphragm Style – 11/2" through 8" Model DV-5 Deluge Valves are diaphragm type valves designed for vertical or horizontal installation for fire protection system service. They are used as "automatic water control valves" in deluge, preaction, and special types of fire protection systems such as foam-water systems. When properly trimmed, the DV-5 Valves provide actuation of fire alarms upon system operation. The unique diaphragm style design of the DV-5 Valve allows external resetting. Deluge or preaction systems can be reset without having to open a valve handhole cover and manually reposition a clapper or latch mechanism.
Deluge Valve, External Resetting Diaphragm Style – 11/2" thru 8" Model DV-5 Deluge Valves are diaphragm type valves designed for vertical or horizontal installation for fire protection system service.
x
Grooved Fittings, Ductile Iron
Grooved Fittings, Ductile Iron
Provide an economical and efficient method of changing direction, adding an outlet, reducing or capping grooved piping systems
Cast grooved fittings provide full flow characteristics
Full back stop behind the groove to ensure proper coupling engagement and rigidity
Wide range of grooved fabricated fittings also available
90° elbows and tees are also available in the "short pattern" style
Available painted or galvanized finish
Listings and Approvals: UL, ULC, FM, VdS, & LPCB
300 psi pressure rated
x
Mechanical Tees and Crosses Threaded and Grooved Outlet
Mechanical Tees and Crosses Threaded and Grooved Outlet
Threaded or grooved outlet
May be used for any tee connection where a threaded or grooved outlet is needed
It can be used in place of a tee, a cross connection, or a welded outlet where a threaded or grooved outlet is needed
The Mechanical Tee is ideal for use in retrofit or equipment hookup installations as it can be positioned along the pipe at the proper location in the field, ensuring exact lineup of the branch outlet connection
Listings and Approvals: UL, ULC, FM, VdS, & LPCB
Run sizes in 2" to 8" outlets (DN50 to DN200)
Branch sizes in 1/2" to 4" outlets (DN15 to DN100)
x
Flange Adapters 2" to 12" (DN50 to DN300)
Flange Adapters 2" to 12" (DN50 to DN300)
Available sizes: 2" (DN50) through 12" (DN300)
Allows a direct transition from flanged components to a grooved piping system
Bolt patterns conform to ANSI Class 125 and 150, or PN16 standards
Listings and Approvals: UL, ULC, FM, VdS, & LPCB
x
Flexible Reducing Coupling
Flexible Reducing Coupling
Available sizes: 1" (DN25) through 12" (DN300)
The GRINNELL G-FIRE Figure 705 Flexible Coupling is capable of pressures up to 300 psi (20,7 bar) depending on pipe size and wall thickness when used in fire protection services. It provides a dependable method of joining pipe and is suitable for use in a variety of applications
Listings and Approvals: UL, ULC, FM, VdS, & LPCB
x
Photoelectric Smoke Detector
Photoelectric Smoke Detector
The 2351E photoelectric smoke detector forms part of the Series 300 range of conventional detectors. This range of detectors has been produced using the latest in manufacturing and design techniques, pushing out the boundaries of existing conventional detector technology. With its multitude of innovative features, the Series 300 is a detector which 'acts conventionally, thinks intelligently'.
x
Rate of Rise Heat Detector with 60°C
Rate of Rise Heat Detector with 60°C
The 5351E thermal detector forms part of the Series 300 range of conventional detectors. This range of detectors has been produced using the latest in manufacturing and design techniques, pushing out the boundaries of existing conventional detector technology. With its multitude of innovative features, the Series 300 is a detector which 'acts conventionally, thinks intelligently'.
x
Micro Environment Suppression System
Micro Environment Suppression System
Size Variants: 100/200/300/400/500 gms
Introducing the Ceasefire Mini, the biggest, smallest suppression system in town; and proof that some of the best thing do come in small packages.
x
Kitchen Suppression System
Kitchen Suppression System
Cylinder size with or without cabinet : 10/25/50 liters
Cylinder construction material : Stainless Steel
Mist micron size : 50 to 80 microns
Working Pressure of Cylinder : 15 Bar
Extinguisher and propelling agent media : Water and Nitrogen
Pipe & Fitting construction material : SS 304/316
Types of nozzles : CSFH -8-10-12
x
Conventional / Addressable Fire Alarm System
Conventional / Addressable Fire Alarm System
The Horizon series of conventional control panels has been developed to provide a simple and reliable solution to the demands of today's fire detection solutions.
x
Beam Detector
Beam Smoke Detector
Optical Beam Detector based on reflective technology. (Suitable for 10m to 70m)
x
Conventional Call Point
Conventional Call Point
Flush call point with 470 Ohm resistor and N.O. contact. Complete with glass.
A simple modular design introduces plug-in terminations to the MCP series installation process. First fix installation permits all field wiring to be terminated to the plug, whilst the fascia element and lid are kept out of harms way. To help the installer further, a simple loop continuity device is included to aid checking of loop wiring before connection to the MCP and the fire alarm system. This new, standard, conventional, break glass offers both clean and monitored contacts in the same housing.
Plug-in terminations
Improved aesthetics
Monitored or clean contacts
Anti-tamper features
Interchangeable glass or re-settable elements
Integrated design
Single maintenan
x
ABC Powder Based Fire Extinguishers
ABC Powder Based Fire Extinguishers
ABC Dry Powder Fire Extinguishers are effective against all classes of fires i.e Class A, Class B, Class C and Electrically started fires. Ceasefire's ABC Dry Powder Fire extinguishers contain a specialized Mono Ammonium Phosphate (MAP) Powder that kills fires in no time.
x
Clean Agent Based Fire Extinguishers
Clean Agent Based Fire Extinguishers
Clean Agent Fire Extinguishers range is perfect for areas where there is an abundance of ultra-sensitive electronic equipments. These extinguishers reduce post-fire damage as they leave no residue behind. The range comes in HCFC123 and HFC 236fa Gas Variants and are completely safe to be used on sensitive equipments. View all clean agent based extinguishers.
x
Carbon Dioxide (Co2) Based Fire Extinguishers
Carbon Dioxide (Co2) Based Fire Extinguishers
CO2 Fire Extinguishers range is most effective against Class B and C Fires. CO2 being a clean agent, these extinguishers are ideal for fire safety of Server Rooms, Labs, IT Rooms, Food Storage & processing areas, etc.